About this product
IEC contactor, TeSys Deca, nonreversing, 95A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 24VDC coil, open style
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 95A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 7.32 inches deep. It weighs 5.75 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product. range TeSys Range of Product TeSys D Product or Component Type Contactor device short name LC1D contactor application Resistive load;Motor control utilisation category AC-1;AC-4;AC-3;AC-3e poles description 3P [Ue] rated operational voltage Power circuit 1000 V AC 25...400 Hz [Ie] rated operational current 95 A 140 °F (60 °C)) <= 440 V AC-3 power circuit;125 A 140 °F (60 °C)) <= 690 V AC-1 power circuit;95 A 140 °F (60 °C)) <= 440 V AC-3e power circuit [Uc] control circuit voltage 24 V DC motor power kW 25 kW 220...230 V AC 50 Hz AC-3);45 kW 380...400 V AC 50 Hz AC-3);45 kW 415...440 V AC 50 Hz AC-3);55 kW 500 V AC 50 Hz AC-3);45 kW 660...690 V AC 50 Hz AC-3);45 kW 1000 V AC 50 Hz AC-3) Maximum Horse Power Rating 7.5 hp 120 V at AC 60 Hz for 1 phase;15 hp 230/240 V at AC 60 Hz for 1 phase;30 hp 200/208 V at AC 60 Hz for 3 phase;30 hp 230/240 V at AC 60 Hz for 3 phase;60 hp 460/480 V at AC 60 Hz for 3 phase;60 hp 575/600 V at AC 60 Hz for 3 phase compatibility code LC1D pole contact composition 3 NO contact compatibility M9 protective cover With [Ith] conventional free air thermal current 10 A 140 °F (60 °C) signalling circuit;125 A 140 °F (60 °C) power circuit Irms rated making capacity 1100 A 440 V AC power circuit IEC 60947;140 A AC signalling circuit IEC 60947-5-1;250 A DC signalling circuit IEC 60947-5-1 rated breaking capacity 1100 A 440 V power circuit IEC 60947 [Icw] rated short-time withstand current 1100 A 104 °F (40 °C) - 1 s power circuit;800 A 104 °F (40 °C) - 10 s power circuit;400 A 104 °F (40 °C) - 1 min power circuit;135 A 104 °F (40 °C) - 10 min power circuit;140 A - 100 ms signalling circuit;120 A - 500 ms signalling circuit;100 A - 1 s signalling circuit associated fuse rating 10 A gG signalling circuit IEC 60947-5-1;200 A gG <= 690 V type 1 power circuit;160 A gG <= 690 V type 2 power circuit average impedance 0.8 mOhm - Ith 125 A 50 Hz power circuit power dissipation per pole 12.5 W AC-1;7.2 W AC-3;7.2 W AC-3e [Ui] rated insulation voltage Power circuit 1000 V IEC 60947-4-1;Signalling circuit 690 V IEC 60947-1 overvoltage category III pollution degree 3 [Uimp] rated impulse withstand voltage 8 kV IEC 60947 safety reliability level B10d = 1.3 Mcycles contactor with nominal load EN/ISO 13849-1;B10d = 20 Mcycles contactor with mechanical load EN/ISO 13849-1 mechanical durability 10 Mcycles electrical durability 1.2 Mcycles 95 A AC-3;1.3 Mcycles 125 A AC-1;1.2 Mcycles 95 A AC-3e control circuit type DC standard coil technology Without built-in suppressor module control circuit voltage limits 0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC;0.85...1.1 Uc -40…131 °F (-40…55 °C) operational DC;1...1.1 Uc 131…158 °F (55…70 °C) operational DC inrush power in W 22 W 68 °F (20 °C)) hold-in power consumption in W 22 W 68 °F (20 °C) operating time 95...130 ms closing;20...35 ms opening time constant 75 ms maximum operating rate 3600 cyc/h 140 °F (60 °C) connections - terminals Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end;Control circuit screw clamp terminals 1 0.00…0.00 in² (1…2.5 mm²) flexible with cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end;Power circuit connector 1 0.01…0.08 in² (4…50 mm²) flexible without cable end;Power circuit connector 2 0.01…0.04 in² (4…25 mm²) flexible without cable end;Power circuit connector 1 0.01…0.08 in² (4…50 mm²) flexible with cable end;Power circuit connector 2 0.01…0.02 in² (4…16 mm²) flexible with cable end;Power circuit connector 1 0.01…0.08 in² (4…50 mm²) solid without cable end;Power circuit connector 2 0.01…0.04 in² (4…25 mm²) solid without cable end tightening torque Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm;Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2;Power circuit 106.21 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm;Power circuit 106.21 lbf.in (12 N.m) connector hexagonal 0.16 in (4 mm);Control circuit 10.62 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2 auxiliary contact composition 1 NO + 1 NC auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1;Mirror contact 1 NC IEC 60947-4-1 signalling circuit frequency 25...400 Hz minimum switching voltage 17 V signalling circuit minimum switching current 5 mA signalling circuit insulation resistance > 10 MOhm signalling circuit non-overlap time 1.5 ms on de-energisation between NC and NO contact;1.5 ms on energisation between NC and NO contact Mounting Support Rail;Plate standards EN/IEC 60947-1;EN/IEC 60947-4-1;EN/IEC 60947-5-1;GB/T 14048.4 Product Certifications IECEE CB Scheme;CCC;EAC;LROS (Lloyds register of shipping);RINA;BV;DNV-GL IP degree of protection IP20 front face IEC 60529 protective treatment THIEC 60068-2-30 climatic withstand IACS E10 exposure to damp heat permissible ambient air temperature around the device -40…140 °F (-40…60 °C);140…158 °F (60…70 °C) with derating operating altitude 0...9842.52 ft (0...3000 m) fire resistance 1562 °F (850 °C) IEC 60695-2-1 flame retardance V1 conforming to UL 94 mechanical robustness Vibrations contactor open 2 Gn;5...300 Hz);Shocks contactor open 8 Gn for 11 ms);Vibrations contactor closed 3 Gn;5...300 Hz);Shocks contactor closed 10 Gn for 11 ms) Height 5.00 in (127 mm) Width 3.35 in (85 mm) Depth 7.32 in (186 mm) Net Weight 5.75 lb(US) (2.61 kg) Category 22359-CTR;TESYS D;OPEN;80-150A AC&DC Discount Schedule I12 GTIN 3389110450576 Returnability No Country of origin CZ Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 4.33 in (11.000 cm) Package 1 Width 6.42 in (16.300 cm) Package 1 Length 8.54 in (21.700 cm) Package 1 Weight 5.66 lb(US) (2.566 kg) Unit Type of Package 2 S02 Number of Units in Package 2 2 Package 2 Height 5.91 in (15.000 cm) Package 2 Width 11.81 in (30.000 cm) Package 2 Length 15.75 in (40.000 cm) Package 2 Weight 12.00 lb(US) (5.445 kg) Unit Type of Package 3 P06 Number of Units in Package 3 32 Package 3 Height 29.53 in (75.000 cm) Package 3 Width 23.62 in (60.000 cm) Package 3 Length 31.50 in (80.000 cm) Package 3 Weight 215.82 lb(US) (97.892 kg) Warranty 18 monthsResources
Description supplied by Blackhawk Supply through its current Shopify listing. Product, performance, and health claims are the seller’s and have not been independently verified by StorkScout.






