Skip to main content

LC1D806G7 | IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 120VAC 50/60Hz coil, open style | Square D

Sold by Blackhawk Supply

Sponsored
LC1D806G7 | IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 120VAC 50/60Hz coil, open style | Square D
$471.99

Opens blackhawksupply.com in a new tab. The seller handles checkout, shipping, and returns.

We may earn a commission when you buy through product links. Sponsored labels identify paid placements from Shopify. We select the Weekly Edit independently. How we make money

Price and availability requested live for this page. Final details are set by the seller.

Share

A closer fit

Find this, but…

Start with this listing, then change what matters. Matches come live from independent Shopify shops and are separate from StorkScout’s Weekly Edit.

Searches start with new, available products that ship to and from the U.S.

What would suit you better?

Try “folds for air travel” or “same shape, without plastic.”

About this product

IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, 3 phase, 3 pole, 3 NO, 120VAC 50/60Hz coil, open style

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 80A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Contactor is also rated for 7.5HP at 115VAC and 15HP at 240VAC single phase. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Ring-lug screw terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product. range TeSys Range of Product TeSys D Product or Component Type Contactor device short name LC1D contactor application Motor control;Resistive load utilisation category AC-1;AC-4;AC-3;AC-3e poles description 3P [Ue] rated operational voltage Power circuit <= 300 V DC 25...400 Hz;Power circuit <= 690 V AC [Ie] rated operational current 125 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit;80 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit;80 A 140 °F (60 °C)) <= 440 V AC AC-3e power circuit [Uc] control circuit voltage 120 V AC 50/60 Hz motor power kW 22 kW 220...230 V AC 50/60 Hz;37 kW 380...400 V AC 50/60 Hz;45 kW 415...440 V AC 50/60 Hz;55 kW 500 V AC 50/60 Hz;45 kW 660...690 V AC 50/60 Hz;45 kW 1000 V AC 50/60 Hz Maximum Horse Power Rating 7.5 hp 120 V at AC 50/60 Hz for 1 phase;15 hp 230/240 V at AC 50/60 Hz for 1 phase;30 hp 200/208 V at AC 50/60 Hz for 3 phase;30 hp 230/240 V at AC 50/60 Hz for 3 phase;60 hp 460/480 V at AC 50/60 Hz for 3 phase;60 hp 575/600 V at AC 50/60 Hz for 3 phase compatibility code LC1D pole contact composition 3 NO contact compatibility M11 protective cover With [Ith] conventional free air thermal current 10 A 140 °F (60 °C) signalling circuit;125 A 140 °F (60 °C) power circuit Irms rated making capacity 140 A AC signalling circuit IEC 60947-5-1;250 A DC signalling circuit IEC 60947-5-1;1100 A 440 V power circuit IEC 60947 rated breaking capacity 1100 A 440 V power circuit IEC 60947 [Icw] rated short-time withstand current 640 A 104 °F (40 °C) - 10 s power circuit;990 A 104 °F (40 °C) - 1 s power circuit;135 A 104 °F (40 °C) - 10 min power circuit;320 A 104 °F (40 °C) - 1 min power circuit;100 A - 1 s signalling circuit;120 A - 500 ms signalling circuit;140 A - 100 ms signalling circuit associated fuse rating 10 A gG signalling circuit IEC 60947-5-1;200 A gG <= 690 V type 1 power circuit;160 A gG <= 690 V type 2 power circuit average impedance 0.8 mOhm - Ith 125 A 50 Hz power circuit power dissipation per pole 5.1 W AC-3;12.5 W AC-1;5.1 W AC-3e [Ui] rated insulation voltage Power circuit 600 V CSA;Power circuit 600 V UL;Power circuit 1000 V IEC 60947-4-1;Signalling circuit 690 V IEC 60947-1;Signalling circuit 600 V CSA;Signalling circuit 600 V UL overvoltage category III pollution degree 3 [Uimp] rated impulse withstand voltage 8 kV IEC 60947 safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1;B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 mechanical durability 4 Mcycles electrical durability 0.8 Mcycles 125 A AC-1 <= 440 V;1.5 Mcycles 80 A AC-3 <= 440 V;1.5 Mcycles 80 A AC-3e <= 440 V control circuit type AC 50/60 Hz coil technology Without built-in suppressor module control circuit voltage limits 0.85...1.1 Uc -40…131 °F (-40…55 °C) operational AC 60 Hz;0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz;0.8...1.1 Uc -40…131 °F (-40…55 °C) operational AC 50 Hz;1...1.1 Uc 131…158 °F (55…70 °C) operational AC 50/60 Hz inrush power in VA 245 VA 60 Hz 0.75 68 °F (20 °C));245 VA 50 Hz 0.75 68 °F (20 °C)) hold-in power consumption in VA 26 VA 60 Hz 0.3 68 °F (20 °C));26 VA 50 Hz 0.3 68 °F (20 °C)) maximum operating rate 3600 cyc/h 140 °F (60 °C) tightening torque Control circuit 10.62 lbf.in (1.2 N.m) lugs-ring terminals flat Ø 6 mm M3.5;Control circuit 10.62 lbf.in (1.2 N.m) lugs-ring terminals Philips No 2 M3.5;Power circuit 106.21 lbf.in (12 N.m) lugs-ring terminals flat Ø 8 mm M6;Power circuit 106.21 lbf.in (12 N.m) lugs-ring terminals hexagonal 0.39 in (10 mm) M6;Power circuit 106.21 lbf.in (12 N.m) bars flat Ø 8 mm M6;Power circuit 106.21 lbf.in (12 N.m) bars hexagonal 0.39 in (10 mm) M6;Control circuit 10.62 lbf.in (1.2 N.m) lugs-ring terminals pozidriv No 2 M3.5 auxiliary contact composition 1 NO + 1 NC auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1;Mirror contact 1 NC IEC 60947-4-1 signalling circuit frequency 25...400 Hz minimum switching voltage 17 V signalling circuit minimum switching current 5 mA signalling circuit insulation resistance > 10 MOhm signalling circuit non-overlap time 1.5 ms on de-energisation between NC and NO contact;1.5 ms on energisation between NC and NO contact Mounting Support Rail;Plate standards CSA C22.2 No 14;EN 60947-4-1;EN 60947-5-1;IEC 60947-4-1;IEC 60947-5-1;UL 508 Product Certifications BV;LROS (Lloyds register of shipping);DNV;CSA;GOST;GL;RINA;UL;CCC IP degree of protection IP20 front face IEC 60529 climatic withstand IACS E10 operating altitude 0...9842.52 ft (0...3000 m) fire resistance 1562 °F (850 °C) IEC 60695-2-1 flame retardance V1 conforming to UL 94 Height 5.00 in (127 mm) Width 3.35 in (85 mm) Depth 5.12 in (130 mm) Net Weight 3.51 lb(US) (1.59 kg) Category 22359-CTR;TESYS D;OPEN;80-150A AC&DC Discount Schedule I12 GTIN 3389110298246 Returnability Yes Country of origin CZ Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 4.33 in (11.0 cm) Package 1 Width 6.30 in (16.0 cm) Package 1 Length 6.42 in (16.3 cm) Package 1 Weight 3.53 lb(US) (1.6 kg) Warranty 18 months

Resources

Description supplied by Blackhawk Supply through its current Shopify listing. Product, performance, and health claims are the seller’s and have not been independently verified by StorkScout.

Keep exploring

Related current listings to open on StorkScout and compare before visiting a seller.