About this product
IEC contactor, TeSys Deca, nonreversing, 25A resistive, 4 pole, 2 NO and 2 NC, 24VAC 50/60Hz coil, open style
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has two normally open and two normally closed power contacts. Power contacts have a 25A resistive load rating. Contactor is supplied with a 24 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.35 inches tall, 1.77 inches wide and 3.62 inches deep. It weighs 0.80 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product. Range of Product TeSys Deca Product or Component Type Contactor device short name LC1D contactor application Resistive load utilisation category AC-1 poles description 4P [Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz;Power circuit <= 300 V DC [Ie] rated operational current 25 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit [Uc] control circuit voltage 24 V AC 50/60 Hz compatibility code LC1D pole contact composition 2 NO + 2 NC contact compatibility M6 protective cover With [Ith] conventional free air thermal current 25 A 140 °F (60 °C) power circuit;10 A 140 °F (60 °C) signalling circuit Irms rated making capacity 250 A 440 V power circuit IEC 60947;140 A AC signalling circuit IEC 60947-5-1;250 A DC signalling circuit IEC 60947-5-1 rated breaking capacity 250 A 440 V power circuit IEC 60947 [Icw] rated short-time withstand current 105 A 104 °F (40 °C) - 10 s power circuit;210 A 104 °F (40 °C) - 1 s power circuit;30 A 104 °F (40 °C) - 10 min power circuit;61 A 104 °F (40 °C) - 1 min power circuit;100 A - 1 s signalling circuit;120 A - 500 ms signalling circuit;140 A - 100 ms signalling circuit associated fuse rating 10 A gG signalling circuit IEC 60947-5-1;40 A gG <= 690 V type 1 power circuit;25 A gG <= 690 V type 2 power circuit average impedance 2.5 mOhm - Ith 25 A 50 Hz power circuit power dissipation per pole 1.56 W AC-1 [Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1;Power circuit 600 V CSA;Power circuit 600 V UL;Signalling circuit 690 V IEC 60947-1;Signalling circuit 600 V CSA;Signalling circuit 600 V UL overvoltage category III pollution degree 3 [Uimp] rated impulse withstand voltage 6 kV IEC 60947 safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1;B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 mechanical durability 15 Mcycles electrical durability 0.8 Mcycles 25 A AC-1 <= 440 V control circuit type AC 50/60 Hz coil technology Without built-in suppressor module control circuit voltage limits 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz;0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz;0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz;1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz inrush power in VA 70 VA 60 Hz 0.75 68 °F (20 °C));70 VA 50 Hz 0.75 68 °F (20 °C)) hold-in power consumption in VA 7.5 VA 60 Hz 0.3 68 °F (20 °C));7 VA 50 Hz 0.3 68 °F (20 °C)) heat dissipation 2…3 W 50/60 Hz operating time 12...22 ms closing;4...19 ms opening maximum operating rate 3600 cyc/h 140 °F (60 °C) connections - terminals Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end;Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end;Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible with cable end;Power circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end;Power circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end;Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible with cable end;Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end tightening torque Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm;Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2;Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm;Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2;Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2;Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2 auxiliary contact composition 1 NO + 1 NC auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1;Mirror contact 1 NC IEC 60947-4-1 signalling circuit frequency 25...400 Hz minimum switching voltage 17 V signalling circuit minimum switching current 5 mA signalling circuit insulation resistance > 10 MOhm signalling circuit non-overlap time 1.5 ms on de-energisation between NC and NO contact;1.5 ms on energisation between NC and NO contact Mounting Support Rail;Plate standards CSA C22.2 No 14;EN 60947-4-1;EN 60947-5-1;IEC 60947-4-1;IEC 60947-5-1;UL 508;IEC 60335-1 Product Certifications DNV;RINA;GOST;CCC;GL;BV;UL;CSA;LROS (Lloyds register of shipping);UKCA IP degree of protection IP20 front face IEC 60529 protective treatment THIEC 60068-2-30 climatic withstand IACS E10 exposure to damp heat;IEC 60947-1 Annex Q category D exposure to damp heat permissible ambient air temperature around the device -40…140 °F (-40…60 °C);140…158 °F (60…70 °C) with derating operating altitude 0...9842.52 ft (0...3000 m) fire resistance 1562 °F (850 °C) IEC 60695-2-1 flame retardance V1 conforming to UL 94 mechanical robustness Vibrations contactor open 2 Gn;5...300 Hz);Vibrations contactor closed 4 Gn;5...300 Hz);Shocks contactor open 10 Gn for 11 ms);Shocks contactor closed 15 Gn for 11 ms) Height 3.35 in (85 mm) Width 1.77 in (45 mm) Depth 3.62 in (92 mm) Net Weight 0.80 lb(US) (0.365 kg) Category 22354-CTR;TESYS D;OPEN;9-38A AC Discount Schedule I12 GTIN 3389110334166 Returnability Yes Country of origin ID Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 2.17 in (5.5 cm) Package 1 Width 3.74 in (9.5 cm) Package 1 Length 4.72 in (12 cm) Package 1 Weight 13.86 oz (393 g) Unit Type of Package 2 S02 Number of Units in Package 2 16 Package 2 Height 5.91 in (15 cm) Package 2 Width 11.81 in (30 cm) Package 2 Length 15.75 in (40 cm) Package 2 Weight 15.10 lb(US) (6.847 kg) Warranty 18 monthsResources
Description supplied by Blackhawk Supply through its current Shopify listing. Product, performance, and health claims are the seller’s and have not been independently verified by StorkScout.