Skip to main content

626612R Nordyne Limit Switch L165-30F

Sold by HVACpartstore

Sponsored
626612R Nordyne Limit Switch L165-30F, image 1 of 2
1 / 2
$12.95

Opens hvacpartstore.com in a new tab. The seller handles checkout, shipping, and returns.

We may earn a commission when you buy through product links. Sponsored labels identify paid placements from Shopify. We select the Weekly Edit independently. How we make money

Price and availability requested live for this page. Final details are set by the seller.

Share

A closer fit

Find this, but…

Start with this listing, then change what matters. Matches come live from independent Shopify shops and are separate from StorkScout’s Weekly Edit.

Searches start with new, available products that ship to and from the U.S.

What would suit you better?

Try “folds for air travel” or “same shape, without plastic.”

About this product

626612R Nordyne Limit Switch L165-30F 

Normal Stock Item

Product Overview

L165-30F Nordyne limit switch 626612R is an OEM high-limit safety control designed to protect gas furnaces and air handlers from overtemperature conditions. The SPST normally-closed contact opens when internal heat exchanger temperatures exceed 165 °F, interrupting power to burners or blowers. Once the unit cools below its reset point, the switch automatically recloses—ensuring reliable, repeat-cycle protection without manual intervention.


Technical Specifications

Specification Detail Part Number 626612R Model L165-30F Function Automatic-reset high-limit safety switch Trip Temperature 165 °F ± 5 °F Reset Temperature 135 °F ± 5 °F Contact Configuration SPST normally closed Terminal Connections Two 1/4″ male quick-connect spades Mounting Snap-in chassis-mount clip Bulb Size N/A (non-bulb style board-mount design) Housing Material High-temperature phenolic/thermoplastic Operating Ambient Range 32 °F to 175 °F


Cross-Reference Part Numbers

  • Nordyne OEM: 626612R

  • Nordyne variation/SKU: 626561

  • Nordyne (manufacturer): 626612


Compatibility

Fits Nordyne, Nordyne Miller, Intertherm, Coleman, Amana, and private-label furnaces or air handlers originally equipped with an L165-30F automatic-reset limit control. Always verify your furnace data-plate or service manual for the exact limit-switch designation before ordering.


Technician Notes

  • De-energize the furnace at the service disconnect and shut off the gas supply before servicing.

  • Remove the access panel to expose the existing high-limit switch on the heat exchanger or plenum.

  • Photograph or label the two quick-connect terminals to preserve wiring orientation.

  • Press the snap-in clip or depress mounting tabs to unlock and remove the old switch; pull off spade connectors.

  • Align and snap the new 626612R into the bracket until it clicks firmly.

  • Reconnect the spade leads to their original terminals, ensuring full engagement on each lug.

  • Restore power and initiate a heat call; confirm blower or burner circuits de-energize at approximately 165 °F and re-energize near 135 °F.

  • If nuisance trips occur, inspect airflow pathways for blockages, verify inducer and blower operation, and confirm thermostat and filter condition before retesting.

L165-30F limit switch. Size 36TX11. AKA = 626561