B1370920 Goodman limit switch L180-30F
The B1370920 Primary Limit Switch is a genuine OEM Goodman furnace safety control designed to protect heating equipment from overheating conditions. Rated L180-30F, this automatic reset limit switch opens the control circuit when temperatures reach approximately 180°F and resets after temperatures drop by approximately 30°F. Featuring a 7-inch sensing rod and 36T01 switch design, this primary limit switch provides critical temperature monitoring for safe furnace operation and heat exchanger protection.
Designed to original equipment specifications, the B1370920 helps prevent excessive operating temperatures that can damage furnace components and reduce system reliability.
Cross-Reference
- B1370920
- B13709-20
- Goodman B1370920
- L180-30F
- 36T01
- Primary Limit Switch
Direct OEM
Yes – Genuine Goodman OEM replacement limit switch.
Compatible Brands
- Goodman
- Amana
- Janitrol
Used in select furnace applications, including:
- GMT070-3 Series Furnaces
Always verify model compatibility before ordering.
Application
- Gas furnaces
- Primary furnace limit controls
- Heat exchanger temperature protection
- Over-temperature safety circuits
- Residential heating systems
- OEM furnace safety replacement
Related Components
- Rollout switches
- Flame sensors
- Pressure switches
- Control boards
- Blower motors
- Fan limit controls
- Ignitors
- Air filters
Technician Notes
- Temperature rating: L180-30F.
- Switch style: 36T01.
- Probe length: 7 inches.
- Back plate dimensions: 1-7/8" x 2-3/8".
- Automatic reset design.
- Primary furnace safety control.
- Repeated limit trips usually indicate airflow restrictions, dirty filters, blower issues, or overheating conditions.
- Always diagnose the cause of overheating before replacing the limit switch.
Common Symptoms of Failure
- Furnace shuts off during heating cycle
- No heat condition
- Open limit switch fault codes
- Intermittent furnace operation
- Blower runs continuously
- Furnace lockout condition
- High temperature safety trips
Installation Tips
- Disconnect electrical power before servicing.
- Verify temperature rating and probe length match the original switch.
- Inspect wiring terminals for heat damage.
- Install the sensing rod fully into the original mounting location.
- Secure the back plate firmly against the mounting surface.
- Restore power and verify proper furnace operation.
- Check temperature rise and overall airflow.
Recommended Inspection Items
- Air filter condition
- Blower wheel cleanliness
- Blower motor operation
- Heat exchanger condition
- Return air restrictions
- Supply airflow
- Venting system
- Control board diagnostics
- Wiring terminals and connectors