Skip to main content

626619 Nordyne Auto Limit Switch

Sold by HVACpartstore

626619 Nordyne Auto Limit Switch, image 1 of 2
1 / 2
$12.58

Opens hvacpartstore.com in a new tab. The seller handles checkout, shipping, and returns.

We may earn a commission when you buy through product links. Sponsored labels identify paid placements from Shopify. We select the Weekly Edit independently. How we make money

Price and availability requested live for this page. Final details are set by the seller.

Share

A closer fit

Find this, but…

Start with this listing, then change what matters. Matches come live from independent Shopify shops and are separate from StorkScout’s Weekly Edit.

Searches start with new, available products that ship to and from the U.S.

What would suit you better?

Try “folds for air travel” or “same shape, without plastic.”

About this product

626619 Nordyne Auto Limit Switch

Normal Stock Item

Product Overview

The 626619 is an OEM auto-reset auxiliary limit switch for Nordyne and Intertherm gas furnaces. It safeguards the heat exchanger by opening its internal contacts at 140 °F and closing them at 100 °F, providing reliable temperature regulation and system protection.


Technical Specifications

  • Temperature close point: 100 °F (38 °C)

  • Temperature open point: 140 °F (60 °C)

  • Switch type: Normally closed auto-reset limit

  • Electrical rating: 1 A @ 120 VAC

  • Terminals: Two 1/4 inch quick-connect spade connectors

  • Housing: Steel enclosure with bimetallic sensing element

  • Operating ambient: –40 °F to 150 °F

  • Weight: 3.2 oz

Auxiliary limit switch, L140-40F. Size T-O-D36TX11 or INT01EL-6833.

Replaces 626279, 626472 & 626472R.

Cross-Reference Part Numbers

  • Replaces Nordyne 626472, 626472R, and 626279

  • Also sold as 626619R


Compatibility

Designed for Nordyne and Intertherm single-stage gas furnaces (MG1E series models 056, 070, 077, 090) and packaged HVAC units that use an auxiliary limit switch. Always confirm the part number on the furnace’s data plate or service manual before ordering.


Technician Notes

  1. Cut power to the furnace; lock out/tag out all line-voltage and 24 VAC circuits.

  2. Remove the access panel and locate the existing limit switch.

  3. Photograph or label wiring to preserve terminal identification.

  4. Unscrew the mounting bracket and disconnect both spade terminals.

  5. Install the new 626619 switch in the same orientation; torque mounting screws snugly.

  6. Reattach wiring per your reference photos, ensuring tight, corrosion-free connections.

  7. Restore power and observe normal operation: the switch should close at 100 °F and open at 140 °F.

  8. If the switch trips out of sequence, verify airflow, venting, and proper sizing of the heat exchanger before replacing components.

Description supplied by HVACpartstore through its current Shopify listing. Product, performance, and health claims are the seller’s and have not been independently verified by StorkScout.