About this product
IEC contactor, TeSys Deca, reversing, 18A, 10HP at 480VAC, 3 phase, 3 pole, 3 NO, 120VAC 50/60Hz coil, open style
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 18A reversing inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 5HP at 200-208VAC, 5HP at 240VAC, 10HP at 480VAC and 15HP at 600VAC three phase. Contactor is also rated for 1HP at 115VAC and 3HP at 240VAC single phase. Contactor is supplied with a 120 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 3.54 inches wide and 3.39 inches deep. It weighs 1.56 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product. Range TeSys, TeSys Deca Product name TeSys D, TeSys Deca Product or Component Type Reversing contactor Device short name LC2D Contactor application Motor control, Resistive load Utilisation category AC-3, AC-1 Device presentation Preassembled with reversing power busbar Poles description 3P power pole contact composition 3 NO [Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz, Power circuit <= 300 V DC [Ie] rated operational current 18 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit, 32 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit motor power kW 4 kW 220...230 V AC 50 Hz, 7.5 kW 380...400 V AC 50 Hz, 9 kW 415...440 V AC 50 Hz, 10 kW 500 V AC 50 Hz, 10 kW 660...690 V AC 50 Hz motor power HP (UL / CSA) 1 hp 115 V at AC 60 Hz for 1 phase, 3 hp 230/240 V at AC 60 Hz for 1 phase, 5 hp 200/208 V at AC 60 Hz for 3 phase, 5 hp 230/240 V at AC 60 Hz for 3 phase, 10 hp 460/480 V at AC 60 Hz for 3 phase, 15 hp 575/600 V at AC 60 Hz for 3 phase control circuit type AC 50/60 Hz [Uc] control circuit voltage 120 V AC 50/60 Hz Auxiliary contact composition 1 NO + 1 NC [Uimp] rated impulse withstand voltage 6 kV IEC 60947 Overvoltage category III [Ith] conventional free air thermal current 10 A 140 °F (60 °C) signalling circuit, 32 A 140 °F (60 °C) power circuit Irms rated making capacity 140 A AC signalling circuit IEC 60947-5-1, 250 A DC signalling circuit IEC 60947-5-1, 300 A 440 V power circuit IEC 60947 rated breaking capacity 300 A 440 V power circuit IEC 60947 [Icw] rated short-time withstand current 40 A 104 °F (40 °C) - 10 min power circuit, 84 A 104 °F (40 °C) - 1 min power circuit, 145 A 104 °F (40 °C) - 10 s power circuit, 240 A 104 °F (40 °C) - 1 s power circuit, 100 A - 1 s signalling circuit, 120 A - 500 ms signalling circuit, 140 A - 100 ms signalling circuit associated fuse rating 10 A gG signalling circuit IEC 60947-5-1, 50 A gG <= 690 V type 1 power circuit, 35 A gG <= 690 V type 2 power circuit average impedance 2.5 mOhm - Ith 32 A 50 Hz power circuit [Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL electrical durability 1.65 Mcycles 18 A AC-3 <= 440 V, 1 Mcycles 32 A AC-1 <= 440 V power dissipation per pole 0.8 W AC-3, 2.5 W AC-1 Front cover With Interlocking type Electrical and mechanical Mounting Support Plate, Rail standards CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1 Product Certifications DNV, CSA, CCC, UL, GL, LROS (Lloyds register of shipping), BV, RINA, GOST, UKCA connections - terminals Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end, Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end, Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end, Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end, Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid, Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid, Power circuit screw clamp terminals 1 0.00…0.01 in² (1.5…6 mm²)flexible without cable end, Power circuit screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²)flexible without cable end, Power circuit screw clamp terminals 1 0.00…0.01 in² (1…6 mm²)flexible with cable end, Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible with cable end, Power circuit screw clamp terminals 1 0.00…0.01 in² (1.5…6 mm²)solid, Power circuit screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²)solid tightening torque Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm, Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2, Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm, Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2, Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2, Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2 operating time 12...22 ms closing, 4...19 ms opening safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 Mechanical durability 15 Mcycles maximum operating rate 3600 cyc/h 140 °F (60 °C) Coil technology Without built-in suppressor module control circuit voltage limits 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz, 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz, 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz, 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz inrush power in VA 70 VA 60 Hz 0.75 68 °F (20 °C)), 70 VA 50 Hz 0.75 68 °F (20 °C)) hold-in power consumption in VA 7.5 VA 60 Hz 0.3 68 °F (20 °C)), 7 VA 50 Hz 0.3 68 °F (20 °C)) heat dissipation 2…3 W 50/60 Hz auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1 Signalling circuit frequency 25...400 Hz minimum switching current 5 mA signalling circuit minimum switching voltage 17 V signalling circuit non-overlap time 1.5 ms on de-energisation between NC and NO contact, 1.5 ms on energisation between NC and NO contact insulation resistance > 10 MOhm signalling circuit IP degree of protection IP20 front face IEC 60529 climatic withstand IACS E10, IEC 60947-1 Annex Q category D protective treatment TH IEC 60068-2-30 Pollution degree 3 ambient air temperature for operation -40…140 °F (-40…60 °C), 140…158 °F (60…70 °C) with derating Ambient Air Temperature for Storage -76…176 °F (-60…80 °C) operating altitude 0...9842.52 ft (0...3000 m) fire resistance 1562 °F (850 °C) IEC 60695-2-1 flame retardance V1 conforming to UL 94 mechanical robustness Vibrations contactor open2 Gn, 5...300 Hz, Vibrations contactor closed4 Gn, 5...300 Hz, Shocks contactor open10 Gn for 11 ms, Shocks contactor closed15 Gn for 11 ms Height 3.03 in (77 mm) Width 3.54 in (90 mm) Depth 3.39 in (86 mm) Net Weight 1.56 lb(US) (0.707 kg) Category 22354-CTR,TESYS D,OPEN,9-38A AC Discount Schedule I12 GTIN 3389110412246 Returnability Yes Country of origin FR Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 3.70 in (9.4 cm) Package 1 Width 4.49 in (11.4 cm) Package 1 Length 4.33 in (11.0 cm) Package 1 Weight 25.75 oz (730.0 g) Warranty 18 monthsResources
Description supplied by Blackhawk Supply through its current Shopify listing. Product, performance, and health claims are the seller’s and have not been independently verified by StorkScout.






