TeSys D Contactor, 3-Poles (3 NO), 50A, 24V DC Coil, Non-Reversing
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 50A/690V AC-3/3e (22kW@400V). It provides a 24V DC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by screw terminals, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (75mm width), DIN-rail mounting or screw fixing. Multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHs/Reach). Range TeSys Range of product TeSys Deca Product or component type Contactor device short name LC1D contactor application Resistive loadResistive load Utilisation category AC-2
AC-4
AC-3
AC-3e
AC-4 Poles description 3P [Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz [Ie] rated operational current 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
50 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
50 A (at <60 °C) at <= 440 V AC AC-3 for power circuit [Uc] control circuit voltage 24 V DC Motor power kW 25 kW at 415 V AC 50 Hz (AC-3)
30 kW at 440 V AC 50 Hz (AC-3)
30 kW at 500 V AC 50 Hz (AC-3)
33 kW at 660...690 V AC 50 Hz (AC-3)
15 kW at 220...230 V AC 50 Hz (AC-3)
11 kW at 400 V AC 50 Hz (AC-4)
30 kW at 1000 V AC 50 Hz (AC-3)
22 kW at 380...400 V AC 50 Hz (AC-3e)
25 kW at 415 V AC 50 Hz (AC-3e)
30 kW at 440 V AC 50 Hz (AC-3e)
30 kW at 500 V AC 50 Hz (AC-3e)
33 kW at 660...690 V AC 50 Hz (AC-3e)
15 kW at 220...230 V AC 50 Hz (AC-3e)
30 kW at 1000 V AC 50 Hz (AC-3e)
22 kW at 380...400 V AC 50 Hz (AC-3) Motor power hp 7.5 hp at 230/240 V AC 60 Hz for 1 phase motors
15 hp at 200/208 V AC 60 Hz for 3 phases motors
15 hp at 230/240 V AC 60 Hz for 3 phases motors
40 hp at 460/480 V AC 60 Hz for 3 phases motors
40 hp at 575/600 V AC 60 Hz for 3 phases motors
3 hp at 115 V AC 60 Hz for 1 phase motors Compatibility code LC1D Pole contact composition 3 NO Protective cover With [Ith] conventional free air thermal current 80 A (at 60 °C) for power circuit
10 A (at 60 °C) for control circuit Irms rated making capacity 900 A at 440 V DC for power circuit conforming to IEC 60947
900 A at 440 V for power circuit conforming to IEC 60947
250 A DC for control circuit conforming to IEC 60947-5-1 Rated breaking capacity 900 A at 440 V for power circuit conforming to IEC 60947 Associated fuse rating 100 A gG at <= 690 V coordination type 1 for power circuit
100 A gG at <= 690 V coordination type 2 for power circuit conforming to IEC 60947-5-1
10 A gG for control circuit conforming to IEC 60947-5-1 Power dissipation per pole 9.6 W AC-1
3.7 W AC-3e
3.7 W AC-3 [Ui] rated insulation voltage Control circuit: 600 V UL certified
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified conforming to IEC 60947-1
Control circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-1
Power circuit: 1000 V CSA certified conforming to IEC 60947-4-1
Control circuit: 600 V CSA certified Overvoltage category III [Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947 Safety reliability level B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 Mechanical durability 10000000 cycles Control circuit type DC wide range Coil technology Built-in bidirectional peak limiting diode suppressor Control circuit voltage limits 0.75...1.25 Uc (-40…60 °C):operational DC
1...1.25 Uc (60…70 °C):operational DC
0.1...0.3 Uc (-40…70 °C):drop-out DC Inrush power in W 19 W (at 20 °C) Hold-in power consumption in W 7.4 W at 20 °C Rated operational power in W 48 W at 24 V DC-13 - electrical durability: 3000000 cycles - for control circuit
96 W at 24 V DC-13 - electrical durability: 1000000 cycles - for control circuit
14 W at 24 V DC-13 - electrical durability: 10000000 cycles - for control circuit Operating time 50 ms closing
20 ms opening Time constant 34 ms Maximum operating rate 3600 cyc/h 60 °C Connections - terminals Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: rigid without cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Power circuit: screw terminals 1 2.5…25 mm² - cable stiffness: rigid
Power circuit: screw terminals 2 2.5…16 mm² - cable stiffness: rigid without cable end
Power circuit: screw terminals 1 2.5…25 mm² - cable stiffness: flexible without cable end
Power circuit: screw terminals 2 2.5…16 mm² - cable stiffness: flexible without cable end
Power circuit: screw terminals 1 2.5…25 mm² - cable stiffness: flexible with cable end
Power circuit: screw terminals 2 2.5…10 mm² - cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: rigid
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: rigid Tightening torque Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver Philips No 2
Power circuit: 5 N.m - on screw terminal - with screwdriver flat Ø 6 to Ø 8 mm
Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver pozidriv No 2
Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm auxiliary contact composition 1 NO + 1 NC Auxiliary contacts type type mirror contact 1 NC conforming to IEC 60947-4-1
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 Minimum switching voltage 17 V for control circuit Minimum switching current 5 mA for control circuit Insulation resistance > 10 MOhm for control circuit Non-overlap time 1.5 ms on energisation between NC and NO contacts
1.5 ms on de-energisation between NC and NO contacts Mounting support Plate
Plate Standards CSA C22.2 No 14
IEC 60947-5-1
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1 product certifications CSA
DNV
RINA
BV
CCC
UL
GOST
GL
UKCA
CCC IP degree of protection IP2X conforming to VDE 0106
IP2X conforming to IEC 60529 Climatic withstand conforming to IACS E10 exposure to damp heat Operating altitude 0...3000 m Fire resistance 850 °C conforming to IEC 60695-2-1 Flame retardance V1 conforming to UL 94 Mechanical robustness Shocks contactor closed (15 Gn for 11 ms)
Vibrations contactor opened (2 Gn, 5...300 Hz)
Vibrations contactor closed (4 Gn, 5...300 Hz)
Shocks contactor opened (10 Gn for 11 ms) Height 127 mm Width 85 mm Depth 176 mm Net weight 2.185 kg Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 9.0 cm Package 1 Width 14.0 cm Package 1 Length 18.5 cm Package 1 Weight 2.169 kg Unit Type of Package 2 S02 Number of Units in Package 2 2 Package 2 Height 15 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 4.829 kg Warranty 18 months