About this product
HPC Fire 30-Inch Square Flat Fire Pit Insert
The HPC Fire 30-Inch Square Flat Fire Pit Insert (SKU: TOR-30FSSEI-SQ-HI/LO-NG/24VAC) is a CSA-certified outdoor gas fire pit insert configured for Natural Gas with high/low electronic ignition and 24VAC power.
The manufacturer lists 225,000 BTU for this exact part number.
Quick Answer: Is This the Right Model?
Choose this model if your project calls for a 30-inch square flat fire pit insert using natural gas, high/low electronic ignition, and 24VAC power. Confirm the enclosure, gas supply, electrical service, ventilation, drainage, clearances, and installation requirements before ordering.
Product DetailsProduct Overview
This HPC Fire configuration is designed as a square flat outdoor fire pit insert for installation in a compatible recessed outdoor enclosure.
The exact manufacturer part number is TOR-30FSSEI-SQ-HI/LO-NG/24VAC.
Key Features and Benefits
Model-Specific Configuration
30" Flat Square SS 225k BTU Fire Pit with Hot Surface Ignition, Hi/Low Flame Control, Remote and TOR-PENTA24 Burner — FOR NATURAL GAS and 24VAC APPLICATION ONLY; CSA Certified Model.
The flat square format is intended for a compatible recessed outdoor fire pit enclosure. The fuel, ignition, electrical, and burner configuration must match the project requirements.
High/Low Electronic Ignition
This configuration uses electronic ignition with high/low flame control.
The supplied product description also identifies hot surface ignition and a remote as part of this configuration.
Because the ignition and controls depend on electrical service, the project must account for the specified 24VAC requirement.
Torpedo PENTA Burner
The supplied manufacturer description identifies a TOR-PENTA24 burner for this exact model.
The burner should be treated as part of the complete certified configuration rather than as a separate specification that can be substituted without verifying manufacturer compatibility.
Outdoor Stainless Steel Insert Design
HPC Fire describes its certified square flat insert family as using 304 stainless steel, raised burner hubs, and weep holes for water mitigation.
These family-level characteristics support outdoor use, but all installation and care requirements should be confirmed using the current documentation for the exact product.
Technical Specifications
Installation, Fuel, and Compatibility
Install only in a compatible outdoor enclosure with the correct natural gas supply and 24VAC electrical service.
The manufacturer catalog identifies enclosure ventilation on at least two sides, a minimum 50% free air space, a minimum 2-inch bottom clearance, and size-dependent combustible clearances for the square flat insert family.
Natural Gas Supply
This exact part number is configured specifically for Natural Gas.
The gas supply, piping, pressure, regulator arrangement where applicable, and related components must meet the requirements of the selected model and installation.
24VAC Electrical Service
The electronic ignition system requires 24VAC power.
Electrical service and connections should be planned before the enclosure is completed so the ignition and control system can be installed according to the manufacturer documentation.
Enclosure Planning
The enclosure must be designed around more than the visible pan dimensions.
Cutout dimensions, ventilation, drainage, structural support, electrical access, gas access, serviceability, surrounding materials, and clearances all need to be coordinated with the exact insert.
Ventilation
The manufacturer information for the square flat insert family identifies ventilation requirements on at least two sides of the enclosure and minimum free-air requirements.
Do not cover or obstruct required ventilation openings with decorative finishes, storage areas, landscaping materials, or other enclosure components.
Drainage and Water Management
HPC Fire describes the certified square flat insert family as using raised burner hubs and weep holes for water mitigation.
The complete enclosure should still be planned so water can drain properly and does not become trapped around the burner, controls, or electronic components.
Clearances and Surrounding Materials
Required clearances vary according to the exact product and installation conditions.
Do not apply clearance measurements from another pan size, another HPC model, or another ignition configuration to this 30-inch electronic-ignition model.
What to Confirm Before Ordering
Match the Exact SKU
Confirm TOR-30FSSEI-SQ-HI/LO-NG/24VAC and its fuel, ignition, voltage, burner, and control configuration.
Verify the Enclosure
Check required cutout dimensions, ventilation, drainage, service access, structural support, and clearances against the current manufacturer manual.
Confirm Natural Gas
This model is configured for Natural Gas. Make sure the planned fuel supply matches the exact model requirements before ordering.
Confirm 24VAC Power
This configuration requires 24VAC. Make sure the required electrical service can be provided at the planned installation location.
Verify the Ignition System
This model uses high/low electronic ignition with hot surface ignition and high/low flame control.
Confirm the Burner
The supplied product description identifies the TOR-PENTA24 burner. Verify that all burner and pan components correspond to the exact manufacturer configuration.
Check Package Contents
Confirm the supplied remote, controls, gas connections, approved fire media, power components, and any accessories or installation components sold separately.
Review Installation Documentation
Do not begin enclosure construction from the nominal 30-inch size alone. Use the current technical drawings and installation manual for this exact SKU.
Check Local Requirements
Review applicable local codes, permits, inspections, and professional installation requirements before the project begins.
Review Warranty Coverage
HPC Fire identifies a lifetime burner warranty for this family. Review current written warranty terms for component-specific coverage, electronic components, conditions, and exclusions.
Frequently Asked Questions
This exact SKU is configured for natural gas. Choose a different manufacturer part number when another fuel configuration is required.
The manufacturer lists high/low electronic ignition for SKU TOR-30FSSEI-SQ-HI/LO-NG/24VAC.
Yes. This configuration specifies 24VAC power. Confirm all electrical requirements in the current installation manual.
Yes. The supplied manufacturer description identifies high/low flame control for this exact configuration.
The supplied product description identifies a TOR-PENTA24 burner using HPC Fire's Torpedo PENTA burner design.
The manufacturer lists 225,000 BTU for this exact part number.
The supplied manufacturer information identifies TOR-30FSSEI-SQ-HI/LO-NG/24VAC as a CSA-certified model.
No. The nominal pan size does not establish the required cutout. Use the current manufacturer drawings and installation documentation for the exact SKU.
Verify enclosure dimensions, ventilation, drainage, combustible clearances, structural conditions, natural gas supply, 24VAC electrical service, controls, and the current installation manual for the exact model.
This exact SKU is identified as a natural gas configuration. Do not substitute propane unless the manufacturer specifically approves a conversion for this exact product and the required approved components and procedures are used.
Choose the Correct HPC Fire Configuration Before Building the Enclosure
The HPC Fire TOR-30FSSEI-SQ-HI/LO-NG/24VAC is a 30-inch square flat outdoor fire pit insert configured for Natural Gas, high/low electronic ignition, 24VAC power, a TOR-PENTA24 Torpedo PENTA burner, and a manufacturer-listed output of 225,000 BTU.
Before purchasing, verify the exact SKU, gas supply, electrical service, ignition configuration, enclosure dimensions, ventilation, drainage, combustible clearances, controls, accessories, and current installation documentation.
Plan the complete fire-feature system around the exact manufacturer specifications—not the nominal 30-inch pan size alone.
Description supplied by Flame Authority through its current Shopify listing. Product, performance, and health claims are the seller’s and have not been independently verified by StorkScout.