About this product
HPC Fire 24-Inch Square Flat Fire Pit Insert
The HPC Fire 24-Inch Square Flat Fire Pit Insert (SKU: TOR-24FSSEI-SQ-HI/LO-LP/24VAC) is a CSA-certified outdoor gas fire pit insert configured for Liquid Propane with high/low electronic ignition and 24VAC power.
The manufacturer lists 140,000 BTU for this exact part number.
Quick Answer: Is This the Right Model?
Choose this model if your project calls for a 24-inch square flat fire pit insert using liquid propane, high/low electronic ignition, and 24VAC power. Confirm the enclosure, propane supply, electrical service, ventilation, drainage, clearances, and installation requirements before ordering.
Product DetailsProduct Overview
This HPC Fire configuration is designed as a square flat outdoor fire pit insert for installation in a compatible recessed outdoor enclosure.
The exact manufacturer part number is TOR-24FSSEI-SQ-HI/LO-LP/24VAC.
Key Features and Benefits
Model-Specific Configuration
24" Flat Square SS 140k BTU Fire Pit with Hot Surface Ignition, Hi/Low Flame Control, Remote and TOR-PENTA18 Burner — FOR LP GAS and 24VAC APPLICATION ONLY; CSA Certified Model.
The flat square format is intended for a compatible recessed outdoor fire pit enclosure. The fuel, ignition, electrical, and burner configuration must match the project requirements.
High/Low Electronic Ignition
This configuration uses high/low electronic ignition with hot surface ignition.
The supplied manufacturer description also identifies high/low flame control and a remote as part of this exact configuration.
Because the ignition and controls depend on electrical service, the project must account for the specified 24VAC requirement.
TOR-PENTA18 Burner
The supplied manufacturer description identifies a TOR-PENTA18 burner for this exact configuration.
The burner should be treated as part of the complete configured system together with the pan, liquid-propane supply, ignition system, electrical service, controls, and enclosure requirements.
Outdoor Stainless Steel Insert Design
HPC Fire describes its certified square flat insert family as using 304 stainless steel, raised burner hubs, and weep holes for water mitigation.
These family-level characteristics support outdoor use, but installation and care requirements should be confirmed using the current documentation for the exact product.
Technical Specifications
Installation, Fuel, and Compatibility
Install only in a compatible outdoor enclosure with the correct liquid propane supply and 24VAC electrical service.
The manufacturer catalog identifies enclosure ventilation on at least two sides, a minimum 50% free air space, a minimum 2-inch bottom clearance, and size-dependent combustible clearances for the square flat insert family.
Liquid Propane Supply
This exact part number is configured specifically for Liquid Propane.
The propane supply, piping, gas pressure, regulator arrangement where applicable, and related components must meet the requirements of the exact model and installation.
24VAC Electrical Service
The electronic ignition system requires 24VAC power.
Electrical service should be planned before the enclosure is completed so the ignition, flame-control, and remote-control components can be installed and serviced according to the manufacturer's requirements.
Enclosure Planning
The enclosure must be designed around more than the visible pan dimensions.
Cutout dimensions, ventilation, drainage, structural support, gas access, electrical access, serviceability, surrounding materials, and required clearances all need to be coordinated with the exact insert.
Ventilation
The manufacturer information for the square flat insert family identifies ventilation requirements on at least two sides of the enclosure and minimum free-air requirements.
Do not cover or obstruct required ventilation openings with decorative finishes, storage areas, landscaping materials, or other enclosure components.
Drainage and Water Management
HPC Fire describes the certified square flat insert family as using raised burner hubs and weep holes for water mitigation.
The complete enclosure should still be planned so water can drain properly and does not remain trapped around the burner, controls, electronic components, or gas connections.
Clearances and Surrounding Materials
Required clearances vary according to the exact product and installation conditions.
Do not apply clearance measurements from another pan size, another HPC model, another fuel configuration, ignition configuration, or voltage configuration to this 24-inch LP 24VAC electronic-ignition model.
What to Confirm Before Ordering
Match the Exact SKU
Confirm TOR-24FSSEI-SQ-HI/LO-LP/24VAC and its fuel, ignition, voltage, burner, and control configuration.
Verify the Enclosure
Check required cutout dimensions, ventilation, drainage, structural support, service access, and clearances against the current manufacturer manual.
Confirm Liquid Propane
This model is configured for Liquid Propane. Make sure the planned LP supply matches the exact product requirements.
Confirm 24VAC Power
This configuration requires 24VAC. Make sure the required electrical service can be provided at the planned installation location.
Verify the Ignition System
This model uses high/low electronic ignition with hot surface ignition and high/low flame control.
Confirm the Burner
The supplied product description identifies the TOR-PENTA18 burner. Make sure the burner and pan components correspond to the exact manufacturer configuration.
Check Package Contents
Confirm the supplied remote, controls, gas connections, power components, approved fire media, and any accessories or installation components sold separately.
Review Installation Documentation
Do not begin enclosure construction from the nominal 24-inch size alone. Use the current technical drawings and installation manual for this exact SKU.
Check Local Requirements
Review applicable local codes, permit requirements, inspection requirements, and professional installation requirements before the project begins.
Review Warranty Coverage
HPC Fire identifies a lifetime burner warranty for this family. Review current written terms for burner coverage, electronic-component coverage, conditions, and exclusions.
Frequently Asked Questions
This exact SKU is configured for liquid propane. Choose a different manufacturer part number when another fuel configuration is required.
The manufacturer lists high/low electronic ignition for SKU TOR-24FSSEI-SQ-HI/LO-LP/24VAC.
Yes. This configuration specifies 24VAC power. Confirm the complete electrical requirements in the current manufacturer installation manual.
Yes. The supplied manufacturer description identifies high/low flame control for this exact configuration.
The supplied manufacturer description identifies a remote as part of this exact high/low electronic-ignition configuration. Confirm current package contents before ordering.
The supplied product description identifies a TOR-PENTA18 burner using HPC Fire's Torpedo PENTA burner design.
The manufacturer lists 140,000 BTU for this exact part number.
The supplied manufacturer information identifies TOR-24FSSEI-SQ-HI/LO-LP/24VAC as a CSA-certified model.
No. The nominal pan size does not establish the required cutout. Use the current manufacturer drawings and installation documentation for the exact SKU.
Verify enclosure dimensions, ventilation, drainage, combustible clearances, structural conditions, liquid-propane supply, 24VAC electrical service, controls, service access, and the current installation manual for the exact model.
This exact SKU is identified as a liquid-propane configuration. Do not substitute natural gas unless the manufacturer specifically approves a conversion for this exact model and the required approved components and procedures are used.
Choose the Correct HPC Fire Configuration Before Building the Enclosure
The HPC Fire TOR-24FSSEI-SQ-HI/LO-LP/24VAC is a 24-inch square flat outdoor fire pit insert configured for Liquid Propane, high/low electronic ignition, 24VAC power, a TOR-PENTA18 burner, and a manufacturer-listed output of 140,000 BTU.
Before purchasing, verify the exact SKU, propane supply, electrical service, ignition configuration, enclosure dimensions, ventilation, drainage, combustible clearances, controls, accessories, and current installation documentation.
Plan the complete fire-feature system around the exact manufacturer specifications—not the nominal 24-inch pan size alone.
Description supplied by Flame Authority through its current Shopify listing. Product, performance, and health claims are the seller’s and have not been independently verified by StorkScout.






