About this product
S1-026-34028-001 York L155F-30 Coleman 3" limit switch
The S1-026-34028-001 L155F-30 Limit Switch is a genuine OEM Coleman and York furnace safety control designed to protect the heat exchanger from overheating. Rated to open at 155°F with a 30°F differential, this automatic reset limit switch interrupts burner operation when excessive temperatures are detected and restores operation once temperatures return to a safe range. Featuring a 3-inch insertion length and a mounting plate measuring 1-7/8" x 2-3/4", this switch is commonly used in Coleman PTUHB furnaces and all G8C series units.
Cross‑Reference
- S1-026-34028-001
- 026-34028-001
- S1-02634028001
- 026-34726-002
- 2702-315P/A
- 2702-3151/A
- 2702-315P
- 2702-315
- L155F-30
- 1NT17L
- 36T01B3
Direct OEM
Yes, Genuine OEM Coleman / York Limit Switch.
Compatible Brands
- Coleman
- York
- Luxaire
- Fraser-Johnston
Verify model and serial number compatibility before ordering.
Application
- Coleman PTUHB Furnaces
- Coleman G8C Series Furnaces
- Residential Gas Furnaces
- Mobile Home Furnaces
- Furnace Over-Temperature Protection Circuits
Specifications
- Temperature Rating: L155°F
- Differential: 30°F
- Insertion Length: 3"
- Mounting Plate Size: 1-7/8" x 2-3/4"
- Auto Reset Design
Related Components
- Flame Sensors
- Pressure Switches
- Blower Motors
- Run Capacitors
- Control Boards
- Rollout Switches
- Induced Draft Motors
- Fan Limit Controls
- Air Filters
- Heat Exchanger Components
Technician Notes
- A failed limit switch is often a symptom rather than the root cause.
- Always inspect airflow-related components before replacing the switch.
- Verify blower performance and temperature rise across the heat exchanger.
- Check for dirty evaporator coils, blocked vents, or restricted filters.
- Replace any limit switch showing signs of overheating, pitted terminals, or intermittent operation.
Common Symptoms of Failure
- Furnace will not fire
- Burners shut off prematurely
- Furnace short cycles
- High-limit fault codes
- Intermittent heating
- Blower runs continuously
- Lockout conditions
- Excessive cabinet temperatures
Installation Tips
- Disconnect electrical power to the furnace.
- Verify the replacement switch matches the original temperature rating.
- Remove wiring from the existing switch.
- Remove mounting screws and old limit switch.
- Install replacement switch securely.
- Reconnect wiring terminals.
- Restore power and test furnace operation.
- Verify proper temperature rise and airflow.
Recommended Inspection Items
- Air Filter Condition
- Blower Wheel Cleanliness
- Blower Motor Operation
- Evaporator Coil
- Supply and Return Airflow
- Heat Exchanger
- Vent System
- Control Board Diagnostics
- Temperature Rise Across Furnace
- Burner Operation
Replaces: 026-34028-001, S1-026-34028-001
L155-30F Coleman 3" limit switch. Back plate measures 1-7/8" x 2-3/4". Replaces 026-34726-002, 2702-315P/A, 2702-3151/A, 2702-315P, 2702-315 & S1-02634028001,. Sizes are 1NT17L or 36T01B3. For use with PTUHB and all G8C units.
Description supplied by HVACpartstore through its current Shopify listing. Product, performance, and health claims are the seller’s and have not been independently verified by StorkScout.