Skip to main content

LC2K1210G7 | Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 12 A, 1 NO, 120VAC coil | Square D

Sold by Blackhawk Supply

Sponsored
LC2K1210G7 | Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 12 A, 1 NO, 120VAC coil | Square D
$170.99

Opens blackhawksupply.com in a new tab. The seller handles checkout, shipping, and returns.

We may earn a commission when you buy through product links. Sponsored labels identify paid placements from Shopify. We select the Weekly Edit independently. How we make money

Price and availability requested live for this page. Final details are set by the seller.

Share

A closer fit

Find this, but…

Start with this listing, then change what matters. Matches come live from independent Shopify shops and are separate from StorkScout’s Weekly Edit.

Searches start with new, available products that ship to and from the U.S.

What would suit you better?

Try “folds for air travel” or “same shape, without plastic.”

About this product

Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 12 A, 1 NO, 120VAC coil

LC2K1210G7 is a compact 3-pole TeSys K reversing contactor from Schneider Electric for motor applications. Rated 12A AC-3 5.5kW@400V, it includes a 120V 50/60Hz AC coil, 2NO auxiliary contacts, a mechanical interlock and pre-wired reversing circuit. LC2K1210G7 is a 3-pole TeSys K reversing contactor from Schneider Electric for simple motor applications rated up to 5.5kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it is assembled with a mechanical interlock and a pre-wired reversing circuit. It includes a 120V 50/60Hz AC coil and 2NO built-in auxiliary contacts. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 90mm wide, for DIN-rail and panel mounting. Assembled with mechanical interlock and pre-wired reversing circuit. Provides a 120V AC coil compatible 50/60Hz and 2NO built-in auxiliary contact. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K). Range TeSys Product name TeSys K Product or Component Type Reversing contactor Device short name LC2K Device Application Control Contactor application Resistive load, Motor control Utilisation category AC-4, AC-1, AC-3, AC-3e Device presentation Preassembled with reversing power busbar Poles description 3P power pole contact composition 3 NO [Ue] rated operational voltage Power circuit 690 V AC 50/60 Hz, Signalling circuit <= 690 V AC 50/60 Hz [Ie] rated operational current 20 A 122 °F (50 °C)) <= 440 V AC AC-1 power circuit, 16 A 158 °F (70 °C)) 690 V AC AC-1 power circuit, 12 A<= 440 V AC AC-3 power circuit, 12 A<= 440 V AC AC-3e power circuit motor power kW 4 kW 480 V AC 50/60 Hz, 4 kW 500...600 V AC 50/60 Hz, 4 kW 660...690 V AC 50/60 Hz, 3 kW 220...230 V AC 50/60 Hz, 5.5 kW 380...415 V AC 50/60 Hz, 5.5 kW 440 V AC 50/60 Hz control circuit type AC 50/60 Hz [Uc] control circuit voltage 120 V AC 50/60 Hz Auxiliary contact composition 1 NO [Uimp] rated impulse withstand voltage 8 kV Overvoltage category III [Ith] conventional free air thermal current 20 A 122 °F (50 °C) power circuit, 10 A 122 °F (50 °C) signalling circuit Irms rated making capacity 144 A 690 V AC power circuit NF C 63-110, 144 A 690 V AC power circuit IEC 60947, 110 A AC signalling circuit IEC 60947 rated breaking capacity 110 A 440 V IEC 60947, 80 A 500 V IEC 60947, 70 A 660...690 V IEC 60947 [Icw] rated short-time withstand current 115 A 122 °F (50 °C) - 1 s power circuit, 105 A 122 °F (50 °C) - 5 s power circuit, 100 A 122 °F (50 °C) - 10 s power circuit, 75 A 122 °F (50 °C) - 30 s power circuit, 55 A 122 °F (50 °C) - 1 min power circuit, 50 A 122 °F (50 °C) - 3 min power circuit, 80 A - 1 s signalling circuit, 90 A - 500 ms signalling circuit, 110 A - 100 ms signalling circuit, 25 A 122 °F (50 °C) - >= 15 min power circuit associated fuse rating 25 A gG <= 440 V power circuit, 25 A aM power circuit, 10 A gG signalling circuit IEC 60947, 10 A gG signalling circuit VDE 0660 average impedance 3 mOhm - Ith 20 A 50 Hz power circuit [Ui] rated insulation voltage Power circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-5-1, Signalling circuit 600 V UL 508, Power circuit 600 V CSA C22.2 No 14, Signalling circuit 600 V CSA C22.2 No 14 electrical durability 0.3 Mcycles 20 A AC-1 <= 440 V, 1.3 Mcycles 12 A AC-3 <= 440 V, 1.3 Mcycles 12 A AC-3e <= 440 V Interlocking type Mechanical Mounting Support Plate, Rail standards IEC 60947, VDE 0660, BS 5424, NF C 63-110 Product Certifications UL, CSA, UKCA connections - terminals screw clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid, screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible without cable end, screw clamp terminals 1 0.00…0.00 in² (0.34…2.5 mm²)flexible with cable end, screw clamp terminals 2 0.00…0.01 in² (1.5…4 mm²)solid, screw clamp terminals 2 0.00…0.01 in² (0.75…4 mm²)flexible without cable end, screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²)flexible with cable end tightening torque 7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2, 7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm, 7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals pozidriv No 2 operating time 10...20 ms coil energisation and NO closing, 10...20 ms coil de-energisation and NO opening safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 Mechanical durability 5 Mcycles maximum operating rate 3600 cyc/h control circuit voltage limits Operational 0.8...1.15 Uc 122 °F (50 °C)), Drop-out 0.2...0.75 Uc 122 °F (50 °C)) inrush power in VA 30 VA 68 °F (20 °C)) hold-in power consumption in VA 4.5 VA 68 °F (20 °C)) heat dissipation 1.3 W auxiliary contacts type Instantaneous 1 NO Signalling circuit frequency <= 400 Hz minimum switching current 5 mA signalling circuit minimum switching voltage 17 V signalling circuit non overlap distance 0.02 in (0.5 mm) insulation resistance > 10 MOhm signalling circuit IP degree of protection IP20 VDE 0106 protective treatment TC IEC 60068, TC DIN 50016 Ambient Air Temperature for Operation -13…122 °F (-25…50 °C) Ambient Air Temperature for Storage -58…176 °F (-50…80 °C) operating altitude 6561.68 ft (2000 m) without derating flame retardance V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102 mechanical robustness Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6, Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 Height 2.28 in (58 mm) Width 3.54 in (90 mm) Depth 2.24 in (57 mm) Net Weight 0.86 lb(US) (0.39 kg) Category 22327-CTR,K-LINE,AC,OPEN,REV Discount Schedule I12 GTIN 3389118023208 Returnability Yes Country of origin FR Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 2.36 in (6.0 cm) Package 1 Width 2.56 in (6.5 cm) Package 1 Length 3.62 in (9.2 cm) Package 1 Weight 12.73 oz (361.0 g) Unit Type of Package 2 S02 Number of Units in Package 2 25 Package 2 Height 5.91 in (15.0 cm) Package 2 Width 11.81 in (30.0 cm) Package 2 Length 15.75 in (40.0 cm) Package 2 Weight 20.90 lb(US) (9.48 kg) Warranty 18 months

Resources

Description supplied by Blackhawk Supply through its current Shopify listing. Product, performance, and health claims are the seller’s and have not been independently verified by StorkScout.

Keep exploring

Related current listings to open on StorkScout and compare before visiting a seller.