Skip to main content

LC2D50G7 | TeSys D Contactor, 3-Poles (3 NO), 50A, 120V AC Coil, Reversing | Square D

Sold by Blackhawk Supply

Sponsored
LC2D50G7 | TeSys D Contactor, 3-Poles (3 NO), 50A, 120V AC Coil, Reversing | Square D
$891.99

Opens blackhawksupply.com in a new tab. The seller handles checkout, shipping, and returns.

We may earn a commission when you buy through product links. Sponsored labels identify paid placements from Shopify. We select the Weekly Edit independently. How we make money

Price and availability requested live for this page. Final details are set by the seller.

Share

A closer fit

Find this, but…

Start with this listing, then change what matters. Matches come live from independent Shopify shops and are separate from StorkScout’s Weekly Edit.

Searches start with new, available products that ship to and from the U.S.

What would suit you better?

Try “folds for air travel” or “same shape, without plastic.”

About this product

TeSys D Contactor, 3-Poles (3 NO), 50A, 120V AC Coil, Reversing

TeSys Deca reversing contactor, 3 poles (3NO),for motor control applications 50A/440V,AC-3 22kW@400V. Pre-wired power connections, with mechanical interlock,without electrical interlocking. It provides a 120V 60Hz AC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures reliability and durability to standard applications. Compact (90mm width), with DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EN), Green Premium compliant (RoHS/REACh). Range of product TeSys Deca Product or component type Reversing contactor device short name LC2D contactor application Motor control Utilisation category AC-2
AC-3
AC-4 control circuit type AC Coil type Standard Poles description 3P Pole contact composition 3 NO [Ie] rated operational current Power circuit: 50 A AC AC-3 (at <60 °C) Motor power kW 15 kW at 220...240 V AC 50/60 Hz
22 kW at 380...400 V AC 50/60 Hz
25 kW at 415 V AC 50/60 Hz
30 kW at 440 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
33 kW at 660...690 V AC 50/60 Hz [Uc] control circuit voltage 120 V AC 60 Hz Connections - terminals Control circuit: 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: 1 cable(s) 1…4 mm²solid without cable end
Control circuit: 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: 2 cable(s) 1…4 mm²solid without cable end
Power circuit: 1 cable(s) 1…35 mm²flexible with cable end
Power circuit: 1 cable(s) 1…35 mm²flexible without cable end
Power circuit: 1 cable(s) 1…35 mm²solid without cable end
Power circuit: 2 cable(s) 1…25 mm²flexible with cable end
Power circuit: 2 cable(s) 1…25 mm²flexible without cable end
Power circuit: 2 cable(s) 1…25 mm²solid without cable end
Power circuit: 2 cable(s) 1…35 mm²flexible with cable end
Power circuit: 2 cable(s) 1…35 mm²flexible without cable end
Power circuit: 2 cable(s) 1…35 mm²solid without cable end Assembly style Ready assembled Coil technology Without built-in bidirectional peak limiting diode suppressor Protective cover With Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1 auxiliary contact composition 1 NO + 1 NC Interlocking type Mechanical Control circuit voltage limits Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 °C)
Operational: 0.8...1.1 Uc at 50 Hz (at <60 °C)
Operational: 0.85...1.1 Uc at 60 Hz (at <60 °C) [Ui] rated insulation voltage Control circuit: 600 V CSA certified
Control circuit: 600 V UL certified
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Control circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-1 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947 Overvoltage category III Mounting support Plate
Rail Flame retardance V1 conforming to UL 94 Tightening torque Control circuit: 1.7 N.m - cable 1…2.5 mm² - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - cable 1…2.5 mm² - with screwdriver Philips No 2
Control circuit: 1.7 N.m - cable 1…4 mm² - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - cable 1…4 mm² - with screwdriver Philips No 2
Power circuit: 5 N.m - cable 1…25 mm² hexagonal screw head
Power circuit: 8 N.m - cable 1…35 mm² hexagonal screw head [Ue] rated operational voltage Power circuit: <= 1000 V AC 25...400 Hz [Ith] conventional free air thermal current 10 A (at 60 °C) for control circuit
80 A (at 60 °C) for power circuit Irms rated making capacity 140 A AC for control circuit conforming to IEC 60947-5-1
900 A at 440 V for power circuit conforming to IEC 60947 Rated breaking capacity 900 A at 440 V for power circuit conforming to IEC 60947 Associated fuse rating 10 A gG for control circuit conforming to IEC 60947-5-1
100 A gG at <= 690 V coordination type 1 for power circuit
100 A gG at <= 690 V coordination type 2 for power circuit Average impedance - Ith 80 A 50 Hz for power circuit Power dissipation per pole 3.7 W AC-3 - Ith 80 A Inrush power in VA 200 VA cos phi 0.75 (at 20 °C)
220 VA cos phi 0.75 (at 20 °C) Hold-in power consumption in VA 20 VA 50 Hz cos phi 0.3 (at 20 °C)
22 VA 60 Hz cos phi 0.3 (at 20 °C)
26 VA 50 Hz cos phi 0.3 (at 20 °C)
26 VA 60 Hz cos phi 0.3 (at 20 °C) Operating time 12...26 ms closing
4...19 ms opening Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 Mechanical durability 6000000 cycles Maximum operating rate 3600 cyc/h 60 °C Minimum switching current 5 mA for control circuit Minimum switching voltage 17 V for control circuit Non-overlap time 1.5 ms on de-energisation between NC and NO contacts
1.5 ms on energisation between NC and NO contacts Insulation resistance > 10 MOhm for control circuit Height 132 mm Width 165 mm Depth 142 mm Net weight 2.4 kg Standards IEC 60947-4-1
CSA C22.2 No 14
UL 508
IEC 60947-5-1
EN 60947-4-1
EN 60947-5-1 product certifications GL
UL
RINA
GOST
CSA
LROS (Lloyds register of shipping)
CCC
DNV
BV
UKCA IP degree of protection IP2X conforming to IEC 60529
IP2X conforming to VDE 0106 Protective treatment TH (pollution degree 3) conforming to IEC 60068 Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -60…80 °C Permissible ambient air temperature around the device -40…70 °C at Uc Operating altitude 3000 m without derating Fire resistance 850 °C conforming to IEC 60695-2-1 Shock resistance 10 gn contactor closed
8 gn contactor opened Vibration resistance 2 gn 5…300 Hz contactor opened
3 gn 5…300 Hz contactor closed Heat dissipation 6…10 W at 50/60 Hz for control circuit Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 17.0 cm Package 1 Width 18.0 cm Package 1 Length 24.8 cm Package 1 Weight 3.285 kg Warranty 18 months

Resources

Description supplied by Blackhawk Supply through its current Shopify listing. Product, performance, and health claims are the seller’s and have not been independently verified by StorkScout.

Keep exploring

Related current listings to open on StorkScout and compare before visiting a seller.