About this product
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NC aux. - 110 V AC coil
LC1K0901F7 is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW@400V, it includes a 110V 50/60Hz AC coil and 1NC auxiliary contact. LC1K0901F7 is a 3-pole TeSys K contactor from Schneider Electric for simple motor applications rated up to 4kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it includes a 110V 50/60Hz AC coil and 1NC built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 45mm wide, for DIN-rail and panel mounting. Provides a control circuit compatible with 50Hz and 60Hz supplies and 1NC built-in auxiliary contact. Optimized for simple power applications. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K). range TeSys Product or Component Type Contactor product name TeSys K device short name LC1K Device Application Control contactor application Resistive load;Motor control utilisation category AC-4;AC-1;AC-3;AC-3e poles description 3P power pole contact composition 3 NO [Ue] rated operational voltage Power circuit 690 V AC 50/60 Hz;Signalling circuit <= 690 V AC 50/60 Hz [Ie] rated operational current 20 A 122 °F (50 °C)) <= 440 V AC AC-1 power circuit;9 A<= 440 V AC AC-3 power circuit;16 A 158 °F (70 °C)) 690 V AC AC-1 power circuit;9 A<= 440 V AC AC-3e power circuit control circuit type AC 50/60 Hz [Uc] control circuit voltage 110 V AC 50/60 Hz motor power kW 2.2 kW 220...230 V AC 50/60 Hz AC-3;4 kW 380...415 V AC 50/60 Hz AC-3;4 kW 440 V AC 50/60 Hz AC-3;4 kW 480 V AC 50/60 Hz AC-3;4 kW 500...600 V AC 50/60 Hz AC-3;4 kW 660...690 V AC 50/60 Hz AC-3;2.2 kW 400 V AC 50/60 Hz AC-4;2.2 kW 220...230 V AC 50/60 Hz AC-3e;4 kW 380...415 V AC 50/60 Hz AC-3e;4 kW 440 V AC 50/60 Hz AC-3e;4 kW 480 V AC 50/60 Hz AC-3e;4 kW 500...600 V AC 50/60 Hz AC-3e;4 kW 660...690 V AC 50/60 Hz AC-3e auxiliary contact composition 1 NC [Uimp] rated impulse withstand voltage 8 kV overvoltage category III [Ith] conventional free air thermal current 20 A 122 °F (50 °C) power circuit;10 A 122 °F (50 °C) signalling circuit Irms rated making capacity 110 A AC power circuit NF C 63-110;110 A AC power circuit IEC 60947;110 A AC signalling circuit IEC 60947 rated breaking capacity 110 A 415 V IEC 60947;110 A 440 V IEC 60947;80 A 500 V IEC 60947;110 A 220...230 V IEC 60947;110 A 380...400 V IEC 60947;70 A 660...690 V IEC 60947 [Icw] rated short-time withstand current 90 A 122 °F (50 °C) - 1 s power circuit;85 A 122 °F (50 °C) - 5 s power circuit;80 A 122 °F (50 °C) - 10 s power circuit;60 A 122 °F (50 °C) - 30 s power circuit;45 A 122 °F (50 °C) - 1 min power circuit;40 A 122 °F (50 °C) - 3 min power circuit;20 A 122 °F (50 °C) - >= 15 min power circuit;80 A - 1 s signalling circuit;90 A - 500 ms signalling circuit;110 A - 100 ms signalling circuit associated fuse rating 25 A gG <= 440 V power circuit;25 A aM power circuit;10 A gG signalling circuit IEC 60947;10 A gG signalling circuit VDE 0660 average impedance 3 mOhm - Ith 20 A 50 Hz power circuit [Ui] rated insulation voltage Power circuit 600 V UL 508;Power circuit 690 V IEC 60947-4-1;Signalling circuit 690 V IEC 60947-4-1;Signalling circuit 690 V IEC 60947-5-1;Signalling circuit 600 V UL 508;Power circuit 600 V CSA C22.2 No 14;Signalling circuit 600 V CSA C22.2 No 14 insulation resistance > 10 MOhm signalling circuit inrush power in VA 30 VA 68 °F (20 °C)) hold-in power consumption in VA 4.5 VA 68 °F (20 °C)) heat dissipation 1.3 W control circuit voltage limits Operational 0.8...1.15 Uc 122 °F (50 °C));Drop-out 0.2...0.75 Uc 122 °F (50 °C)) connections - terminals screw clamp terminals 1 0.00…0.01 in² (1.5…4 mm²)solid;screw clamp terminals 1 0.00…0.01 in² (0.75…4 mm²)flexible without cable end;screw clamp terminals 1 0.00…0.00 in² (0.34…2.5 mm²)flexible with cable end;screw clamp terminals 2 0.00…0.01 in² (1.5…4 mm²)solid;screw clamp terminals 2 0.00…0.01 in² (0.75…4 mm²)flexible without cable end;screw clamp terminals 2 0.00…0.00 in² (0.34…1.5 mm²)flexible with cable end maximum operating rate 3600 cyc/h auxiliary contacts type Instantaneous 1 NC signalling circuit frequency <= 400 Hz minimum switching current 5 mA signalling circuit minimum switching voltage 17 V signalling circuit Mounting Support Plate;Rail tightening torque 7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2;7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm;7.08…11.51 lbf.in (0.8…1.3 N.m) screw clamp terminals pozidriv No 2 operating time 10...20 ms coil de-energisation and NO opening;10...20 ms coil energisation and NO closing safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1;B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 non overlap distance 0.02 in (0.5 mm) mechanical durability 10 Mcycles electrical durability 0.18 Mcycles 20 A AC-1 <= 440 V;1.3 Mcycles 9 A AC-3 <= 440 V;1.3 Mcycles 9 A AC-3e <= 440 V mechanical robustness Shocks contactor closed;on X axis10 Gn for 11 ms IEC 60068-2-27;Shocks contactor closed;on Y axis15 Gn for 11 ms IEC 60068-2-27;Shocks contactor closed;on Z axis15 Gn for 11 ms IEC 60068-2-27;Shocks contactor opened;on X axis6 Gn for 11 ms IEC 60068-2-27;Shocks contactor opened;on Y axis10 Gn for 11 ms IEC 60068-2-27;Shocks contactor opened;on Z axis10 Gn for 11 ms IEC 60068-2-27;Vibrations contactor closed4 Gn;5...300 Hz IEC 60068-2-6;Vibrations contactor opened2 Gn;5...300 Hz IEC 60068-2-6 Height 2.28 in (58 mm) Width 1.77 in (45 mm) Depth 2.24 in (57 mm) Net Weight 0.40 lb(US) (0.18 kg) standards BS 5424;IEC 60947;NF C 63-110;VDE 0660 Product Certifications CSA;UL;UKCA IP degree of protection IP2x VDE 0106 protective treatment TC IEC 60068;TC DIN 50016 Ambient Air Temperature for Storage -58…176 °F (-50…80 °C) operating altitude 6561.68 ft (2000 m) without derating flame retardance V1 conforming to UL 94;Requirement 2 conforming to NF F 16-101;Requirement 2 conforming to NF F 16-102 Category 22326-CTR;K-LINE;AC;OPEN;NONREV Discount Schedule I12 GTIN 3389110428476 Returnability Yes Country of origin ID Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 2.60 in (6.6 cm) Package 1 Width 1.89 in (4.8 cm) Package 1 Length 2.44 in (6.2 cm) Package 1 Weight 6.38 oz (181.0 g) Unit Type of Package 2 S02 Number of Units in Package 2 50 Package 2 Height 5.91 in (15.0 cm) Package 2 Width 11.81 in (30.0 cm) Package 2 Length 15.75 in (40.0 cm) Package 2 Weight 20.71 lb(US) (9.392 kg) Warranty 18 monthsResources
Description supplied by Blackhawk Supply through its current Shopify listing. Product, performance, and health claims are the seller’s and have not been independently verified by StorkScout.