Skip to main content

LC1D18M7 | TeSys D Contactor, 3-Poles (3 NO), 18A, 220V AC Coil, Non-Reversing | Square D

Sold by Blackhawk Supply

Sponsored
LC1D18M7 | TeSys D Contactor, 3-Poles (3 NO), 18A, 220V AC Coil, Non-Reversing | Square D
$200.99

Opens blackhawksupply.com in a new tab. The seller handles checkout, shipping, and returns.

We may earn a commission when you buy through product links. Sponsored labels identify paid placements from Shopify. We select the Weekly Edit independently. How we make money

Price and availability requested live for this page. Final details are set by the seller.

Share

A closer fit

Find this, but…

Start with this listing, then change what matters. Matches come live from independent Shopify shops and are separate from StorkScout’s Weekly Edit.

Searches start with new, available products that ship to and from the U.S.

What would suit you better?

Try “folds for air travel” or “same shape, without plastic.”

About this product

TeSys D Contactor, 3-Poles (3 NO), 18A, 220V AC Coil, Non-Reversing

TeSys D Contactor
  • Number of Poles: 3-Poles
  • Pole Contact Composition: 3 NO
  • Rated Operational Current: 18A
  • Control Circuit Voltage: 220V AC 50/60 Hz
  • Non-Reversing TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 18A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 5HP at 200-208VAC, 5HP at 240VAC, 10HP at 480VAC and 15HP at 600VAC three phase. Contactor is also rated for 1HP at 115VAC and 3HP at 240VAC single phase. When used with a 480VAC up to 60A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 40A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.03 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.73 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product. Range of Product TeSys Deca Product or Component Type Contactor device short name LC1D contactor application Resistive load;Motor control utilisation category AC-1;AC-4;AC-3;AC-3e poles description 3P [Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz;Power circuit <= 300 V DC [Ie] rated operational current 18 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit;32 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit;18 A 140 °F (60 °C)) <= 440 V AC AC-3e power circuit [Uc] control circuit voltage 220 V AC 50/60 Hz motor power kW 4 kW 220...230 V AC 50/60 Hz AC-3);7.5 kW 380...400 V AC 50/60 Hz AC-3);9 kW 415...440 V AC 50/60 Hz AC-3);10 kW 500 V AC 50/60 Hz AC-3);10 kW 660...690 V AC 50/60 Hz AC-3);4 kW 400 V AC 50/60 Hz AC-4);4 kW 220...230 V AC 50/60 Hz AC-3e);7.5 kW 380...400 V AC 50/60 Hz AC-3e);9 kW 415...440 V AC 50/60 Hz AC-3e);10 kW 500 V AC 50/60 Hz AC-3e);10 kW 660...690 V AC 50/60 Hz AC-3e) Maximum Horse Power Rating 1 hp 115 V at AC 50/60 Hz for 1 phase;3 hp 230/240 V at AC 50/60 Hz for 1 phase;5 hp 200/208 V at AC 50/60 Hz for 3 phase;5 hp 230/240 V at AC 50/60 Hz for 3 phase;10 hp 460/480 V at AC 50/60 Hz for 3 phase;15 hp 575/600 V at AC 50/60 Hz for 3 phase compatibility code LC1D pole contact composition 3 NO contact compatibility M2 protective cover With [Ith] conventional free air thermal current 10 A 140 °F (60 °C) signalling circuit;32 A 140 °F (60 °C) power circuit Irms rated making capacity 140 A AC signalling circuit IEC 60947-5-1;250 A DC signalling circuit IEC 60947-5-1;300 A 440 V power circuit IEC 60947 rated breaking capacity 300 A 440 V power circuit IEC 60947 [Icw] rated short-time withstand current 145 A 104 °F (40 °C) - 10 s power circuit;240 A 104 °F (40 °C) - 1 s power circuit;40 A 104 °F (40 °C) - 10 min power circuit;84 A 104 °F (40 °C) - 1 min power circuit;100 A - 1 s signalling circuit;120 A - 500 ms signalling circuit;140 A - 100 ms signalling circuit associated fuse rating 10 A gG signalling circuit IEC 60947-5-1;50 A gG <= 690 V type 1 power circuit;35 A gG <= 690 V type 2 power circuit average impedance 2.5 mOhm - Ith 32 A 50 Hz power circuit power dissipation per pole 2.5 W AC-1;0.8 W AC-3;0.8 W AC-3e [Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1;Power circuit 600 V CSA;Power circuit 600 V UL;Signalling circuit 690 V IEC 60947-1;Signalling circuit 600 V CSA;Signalling circuit 600 V UL overvoltage category III pollution degree 3 [Uimp] rated impulse withstand voltage 6 kV IEC 60947 safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1;B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 mechanical durability 15 Mcycles electrical durability 1.65 Mcycles 18 A AC-3 <= 440 V;1 Mcycles 32 A AC-1 <= 440 V;1.65 Mcycles 18 A AC-3e <= 440 V control circuit type AC 50/60 Hz standard coil technology Without built-in suppressor module control circuit voltage limits 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz;0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz;0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz;1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz inrush power in VA 70 VA 60 Hz 0.75 68 °F (20 °C));70 VA 50 Hz 0.75 68 °F (20 °C)) hold-in power consumption in VA 7.5 VA 60 Hz 0.3 68 °F (20 °C));7 VA 50 Hz 0.3 68 °F (20 °C)) heat dissipation 2…3 W 50/60 Hz operating time 12...22 ms closing;4...19 ms opening maximum operating rate 3600 cyc/h 140 °F (60 °C) connections - terminals Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible without cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) flexible with cable end;Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²) flexible with cable end;Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²) solid without cable end;Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) solid without cable end;Power circuit screw clamp terminals 1 0.00…0.01 in² (1.5…6 mm²) flexible without cable end;Power circuit screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²) flexible without cable end;Power circuit screw clamp terminals 1 0.00…0.01 in² (1…6 mm²) flexible with cable end;Power circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²) flexible with cable end;Power circuit screw clamp terminals 1 0.00…0.01 in² (1.5…6 mm²) solid without cable end;Power circuit screw clamp terminals 2 0.00…0.01 in² (1.5…6 mm²) solid without cable end tightening torque Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm;Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2;Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm;Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2;Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2;Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2 auxiliary contact composition 1 NO + 1 NC auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1;Mirror contact 1 NC IEC 60947-4-1 signalling circuit frequency 25...400 Hz minimum switching voltage 17 V signalling circuit minimum switching current 5 mA signalling circuit insulation resistance > 10 MOhm signalling circuit non-overlap time 1.5 ms on de-energisation between NC and NO contact;1.5 ms on energisation between NC and NO contact Mounting Support Plate;Rail standards CSA C22.2 No 14;EN 60947-4-1;EN 60947-5-1;IEC 60947-4-1;IEC 60947-5-1;UL 508;IEC 60335-1 Product Certifications GOST;UL;RINA;CCC;DNV;BV;GL;CSA;LROS (Lloyds register of shipping);UKCA IP degree of protection IP20 front face IEC 60529 protective treatment THIEC 60068-2-30 climatic withstand IACS E10 exposure to damp heat;IEC 60947-1 Annex Q category D exposure to damp heat permissible ambient air temperature around the device -40…140 °F (-40…60 °C);140…158 °F (60…70 °C) with derating operating altitude 0...9842.52 ft (0...3000 m) fire resistance 1562 °F (850 °C) IEC 60695-2-1 flame retardance V1 conforming to UL 94 mechanical robustness Vibrations contactor open 2 Gn;5...300 Hz);Vibrations contactor closed 4 Gn;5...300 Hz);Shocks contactor open 10 Gn for 11 ms);Shocks contactor closed 15 Gn for 11 ms) Height 3.03 in (77 mm) Width 1.77 in (45 mm) Depth 3.39 in (86 mm) Net Weight 0.73 lb(US) (0.33 kg) Category 22354-CTR;TESYS D;OPEN;9-38A AC Discount Schedule I12 GTIN 3389110349504 Returnability Yes Country of origin ID Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 1.97 in (5.0 cm) Package 1 Width 3.62 in (9.2 cm) Package 1 Length 4.41 in (11.2 cm) Package 1 Weight 12.42 oz (352.0 g) Unit Type of Package 2 S02 Number of Units in Package 2 20 Package 2 Height 5.91 in (15.0 cm) Package 2 Width 11.81 in (30.0 cm) Package 2 Length 15.75 in (40.0 cm) Package 2 Weight 16.18 lb(US) (7.338 kg) Unit Type of Package 3 P06 Number of Units in Package 3 320 Package 3 Height 29.53 in (75.0 cm) Package 3 Width 23.62 in (60.0 cm) Package 3 Length 31.50 in (80.0 cm) Package 3 Weight 275.53 lb(US) (124.976 kg) Warranty 18 months

    Resources

  • Description supplied by Blackhawk Supply through its current Shopify listing. Product, performance, and health claims are the seller’s and have not been independently verified by StorkScout.

    Keep exploring

    Related current listings to open on StorkScout and compare before visiting a seller.