About this product
TeSys D Contactor, 3P(3 NO), AC-3, <= 440 V 9 A, 24 V DC coil
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 9A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 2HP at 200 to 208VAC, 2HP at 240VAC, 5HP at 480VAC and 7.5HP at 600VAC three phase. Contactor is also rated for 0.33HP at 115VAC and 1HP at 240VAC single phase. Contactor is supplied with a low consumption 24 VDC coil with transient suppressor module. Contactor has one normally open and one normally closed auxiliary contact built-in as stanard. The NC contact is mirror certified. Spring terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.15 inches tall, 1.77 inches wide and 3.74 inches deep. It weighs 1.06 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product. Range of Product TeSys Deca Product or Component Type Contactor device short name LC1D contactor application Resistive load;Motor control utilisation category AC-1;AC-3;AC-4;AC-3e poles description 3P [Ue] rated operational voltage Power circuit <= 690 V AC 25...400 Hz;Power circuit <= 300 V DC [Ie] rated operational current 9 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit;20 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit;9 A 140 °F (60 °C)) <= 440 V AC AC-3e power circuit [Uc] control circuit voltage 24 V DC motor power kW 2.2 kW 220...230 V AC 50/60 Hz AC-3);4 kW 380...400 V AC 50/60 Hz AC-3);4 kW 415...440 V AC 50/60 Hz AC-3);5.5 kW 500 V AC 50/60 Hz AC-3);5.5 kW 660...690 V AC 50/60 Hz AC-3);2.2 kW 400 V AC 50/60 Hz AC-4);2.2 kW 220...230 V AC 50/60 Hz AC-3e);4 kW 380...400 V AC 50/60 Hz AC-3e);4 kW 415...440 V AC 50/60 Hz AC-3e);5.5 kW 500 V AC 50/60 Hz AC-3e);5.5 kW 660...690 V AC 50/60 Hz AC-3e) Maximum Horse Power Rating 1 hp 230/240 V at AC 50/60 Hz for 1 phase;2 hp 200/208 V at AC 50/60 Hz for 3 phase;2 hp 230/240 V at AC 50/60 Hz for 3 phase;5 hp 460/480 V at AC 50/60 Hz for 3 phase;7.5 hp 575/600 V at AC 50/60 Hz for 3 phase;0.33 hp 115 V at AC 50/60 Hz for 1 phase compatibility code LC1D pole contact composition 3 NO contact compatibility M5 protective cover With [Ith] conventional free air thermal current 10 A 140 °F (60 °C) signalling circuit;16 A 140 °F (60 °C) power circuit Irms rated making capacity 250 A 440 V power circuit IEC 60947;140 A AC signalling circuit IEC 60947-5-1;250 A DC signalling circuit IEC 60947-5-1 rated breaking capacity 250 A 440 V power circuit IEC 60947 [Icw] rated short-time withstand current 105 A 104 °F (40 °C) - 10 s power circuit;210 A 104 °F (40 °C) - 1 s power circuit;30 A 104 °F (40 °C) - 10 min power circuit;61 A 104 °F (40 °C) - 1 min power circuit;100 A - 1 s signalling circuit;120 A - 500 ms signalling circuit;140 A - 100 ms signalling circuit associated fuse rating 10 A gG signalling circuit IEC 60947-5-1;25 A gG <= 690 V type 1 power circuit;20 A gG <= 690 V type 2 power circuit average impedance 2.5 mOhm - Ith 16 A 50 Hz power circuit power dissipation per pole 1.56 W AC-1;0.2 W AC-3;0.2 W AC-3e [Ui] rated insulation voltage Power circuit 690 V IEC 60947-4-1;Power circuit 600 V CSA;Power circuit 600 V UL;Signalling circuit 690 V IEC 60947-1;Signalling circuit 600 V CSA;Signalling circuit 600 V UL overvoltage category III pollution degree 3 [Uimp] rated impulse withstand voltage 6 kV IEC 60947 safety reliability level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1;B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 mechanical durability 30 Mcycles electrical durability 0.6 Mcycles 25 A AC-1 <= 440 V;2 Mcycles 9 A AC-3 <= 440 V;2 Mcycles 9 A AC-3e <= 440 V control circuit type DC low consumption coil technology Built-in bidirectional peak limiting diode suppressor control circuit voltage limits 0.1...0.3 Uc -40…158 °F (-40…70 °C) drop-out DC;0.8...1.25 Uc -40…140 °F (-40…60 °C) operational DC;1...1.25 Uc 140…158 °F (60…70 °C) operational DC inrush power in W 2.4 W 68 °F (20 °C)) hold-in power consumption in W 2.4 W 68 °F (20 °C) operating time 65.45...88.55 ms closing;20...30 ms opening time constant 40 ms maximum operating rate 3600 cyc/h 140 °F (60 °C) connections - terminals Power circuit spring terminals 1 0.00 in² (2.5 mm²) flexible without cable end;Power circuit spring terminals 2 0.00 in² (2.5 mm²) flexible without cable end;Control circuit spring terminals 1 0.00 in² (2.5 mm²) flexible without cable end;Control circuit spring terminals 2 0.00 in² (2.5 mm²) flexible without cable end auxiliary contact composition 1 NO + 1 NC auxiliary contacts type Mechanically linked 1 NO + 1 NC IEC 60947-5-1;Mirror contact 1 NC IEC 60947-4-1 signalling circuit frequency 25...400 Hz minimum switching voltage 17 V signalling circuit minimum switching current 5 mA signalling circuit insulation resistance > 10 MOhm signalling circuit non-overlap time 1.5 ms on de-energisation between NC and NO contact;1.5 ms on energisation between NC and NO contact Mounting Support Rail;Plate standards CSA C22.2 No 14;EN 60947-4-1;EN 60947-5-1;IEC 60947-4-1;IEC 60947-5-1;UL 508;IEC 60335-1 Product Certifications UL;GOST;CSA;CCC;GL;BV;LROS (Lloyds register of shipping);DNV;RINA;UKCA IP degree of protection IP20 front face IEC 60529 protective treatment THIEC 60068-2-30 climatic withstand IACS E10 exposure to damp heat;IEC 60947-1 Annex Q category D exposure to damp heat permissible ambient air temperature around the device -40…140 °F (-40…60 °C);140…158 °F (60…70 °C) with derating operating altitude 0...9842.52 ft (0...3000 m) fire resistance 1562 °F (850 °C) IEC 60695-2-1 flame retardance V1 conforming to UL 94 mechanical robustness Vibrations contactor open 2 Gn;5...300 Hz);Vibrations contactor closed 4 Gn;5...300 Hz);Shocks contactor open 10 Gn for 11 ms);Shocks contactor closed 15 Gn for 11 ms) Height 3.90 in (99 mm) Width 1.77 in (45 mm) Depth 3.74 in (95 mm) Net Weight 1.06 lb(US) (0.48 kg) Category 22354-CTR;TESYS D;OPEN;9-38A AC Discount Schedule I12 GTIN 3389110808483 Returnability Yes Country of origin ID Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 2.28 in (5.8 cm) Package 1 Width 4.33 in (11 cm) Package 1 Length 4.84 in (12.3 cm) Package 1 Weight 19.58 oz (555 g) Unit Type of Package 2 S02 Number of Units in Package 2 15 Package 2 Height 5.91 in (15 cm) Package 2 Width 11.81 in (30 cm) Package 2 Length 15.75 in (40 cm) Package 2 Weight 19.61 lb(US) (8.897 kg) Unit Type of Package 3 P06 Number of Units in Package 3 240 Package 3 Height 29.53 in (75 cm) Package 3 Width 23.62 in (60 cm) Package 3 Length 31.50 in (80 cm) Package 3 Weight 331.47 lb(US) (150.352 kg) Warranty 18 monthsResources
Description supplied by Blackhawk Supply through its current Shopify listing. Product, performance, and health claims are the seller’s and have not been independently verified by StorkScout.
