About this product
The Carrier P282-0432A is a heavy-duty 3-pole definite purpose contactor engineered for rigorous commercial and industrial HVACR applications. Designed as a direct OEM replacement contactor, this component features a 120V coil and is rated for a 40 amp Full Load Amperage (FLA), making it suitable for managing high-inductive loads such as compressor motors, large blower fans, and resistance heating elements. Its robust construction includes lug terminals for secure power connections and standard 1/4-inch quick-connects for the coil, ensuring a reliable interface with existing control circuits. Operating at 50/60 Hz and rated for up to 600 VAC, this 40A 3-pole contactor provides synchronized switching across all three lines to protect sensitive three-phase equipment. High-grade Class B insulation on the coil prevents premature failure under thermal stress, providing the durability required for high-cycle environments. This genuine Totaline P282-0432A part ensures structural compatibility and electrical performance, maintaining the efficiency of the original system design while offering broad HVAC part cross-reference versatility across Carrier, Bryant, and Payne families.
Key Benefits for the Technician- Industrial-Grade Ratings: Rated for 40 amps and 600V, providing sufficient overhead for heavy-duty three-phase motor and heating loads.
- Proven Reliability: Features Class B coil insulation and a covered design to mitigate debris ingress and internal shorting.
- Efficient Installation: Equipped with box lug terminals that accommodate 4-14 CU/AL wire, facilitating high-torque, low-resistance connections.
- OEM Precision: Direct replacement for Carrier P282-0432A ensures the footprint and mounting holes align perfectly with the original control panel.
- Can this 120V coil contactor replace a 24V model? No. The coil voltage must match the control circuit output (120V) exactly to prevent either a failure to pull in or immediate coil burnout.
- What causes these 3-pole contactors to chatter? Chattering is typically caused by low voltage at the coil terminals or loose control wiring. Always verify a steady 120VAC signal from the controller under load.
- Is the P282-0432A suitable for resistive loads? Yes, this 40A contactor is rated for both inductive (motors) and resistive (electric heat) applications up to its specified amperage limits.
Item is Non Cancelable / Non Returnable
Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.
Description supplied by GSIstore through its current Shopify listing. Product, performance, and health claims are the seller’s and have not been independently verified by StorkScout.