Skip to main content

Carrier HH12ZA218 Limit Switch

Sold by GSIstore

Sponsored
Carrier HH12ZA218 Limit Switch
$27.51

Opens gsistore.com in a new tab. The seller handles checkout, shipping, and returns.

We may earn a commission when you buy through product links. Sponsored labels identify paid placements from Shopify. We select the Weekly Edit independently. How we make money

Price and availability requested live for this page. Final details are set by the seller.

Share

A closer fit

Find this, but…

Start with this listing, then change what matters. Matches come live from independent Shopify shops and are separate from StorkScout’s Weekly Edit.

Searches start with new, available products that ship to and from the U.S.

What would suit you better?

Try “folds for air travel” or “same shape, without plastic.”

About this product

The Carrier HH12ZA218 Limit Switch is a critical safety component designed for high-efficiency residential heating systems, specifically engineered for furnace limit switch replacement in Carrier, Bryant, and Payne units. This OEM replacement part functions as a normally closed switch that breaks the electrical circuit when the internal plenum temperature exceeds the 180-220F safety threshold. As an auto reset limit switch, it automatically re-engages once temperatures return to safe operating levels, preventing recursive furnace short cycling caused by restricted airflow or blower failure. Built for precision and long-term durability, the HH12ZA218 ensures the heat exchanger does not exceed its thermal rating, protecting the equipment from stress cracks and potential fire hazards. For contractors, this high-limit safety switch offers a direct-fit solution with standardized mounting, ensuring seamless integration into the existing control string. Maintaining proper oven and furnace safety depends on the rapid response time provided by this factory-authorized part.

Key Benefits:
  • Precise Thermal Protection: Engineered to trip within the 180-220 degree Fahrenheit range to prevent catastrophic overheating of the heat exchanger.
  • Automatic Reset Functionality: Minimizes system downtime by automatically restoring power to the heating sequence once safe ambient temperatures are restored.
  • Broad Compatibility: Serves as the primary Carrier furnace part for numerous 58STA and PG8JAA gas furnace models.
  • Rugged Component Construction: Designed to withstand the high-cycle demands of modern HVAC equipment without premature calibration drift.
Common Questions:
  • What causes this limit switch to trip repeatedly? Frequent tripping is usually indicative of restricted airflow. Inspect for a clogged air filter, blocked return ducts, or a malfunctioning blower motor that is failing to move sufficient CFM across the heat exchanger.
  • How do I verify if the HH12ZA218 is faulty? Use a multimeter to check for continuity across the terminals. Since this is a normally closed (NC) switch, you should find zero resistance at room temperature; an open circuit while cool indicates the switch has failed.
  • Is this switch compatible with 80% and 90% AFUE furnaces? Yes, this specific temperature profile is common across a wide range of Carrier-produced gas furnace platforms. Always verify the temperature stamping on the old bracket before installation.

Disclaimer: While we strive for 100% accuracy, product data and specifications are subject to change. Please contact our team to confirm compatibility or technical details before purchasing.

Description supplied by GSIstore through its current Shopify listing. Product, performance, and health claims are the seller’s and have not been independently verified by StorkScout.

Keep exploring

Related current listings to open on StorkScout and compare before visiting a seller.